Amp Mad Scientist
Ambassador of Heresy
Problem: underrated coupling caps at PI output.
Symptom: Bias voltage pin 5 shows failure on 2 output tube sockets.
Heads up: if your PI output coupling caps are rated 400 volt, I suggest you change them to 600 volt rating.
This "is" the second bad capacitor I have replaced in the last 15 amp repairs.
It actually had a shorted coupling cap at the phase inverter output.
Standard Test Procedure: can help you find and solve this problem.

Symptom: Bias voltage pin 5 shows failure on 2 output tube sockets.
Heads up: if your PI output coupling caps are rated 400 volt, I suggest you change them to 600 volt rating.
This "is" the second bad capacitor I have replaced in the last 15 amp repairs.
It actually had a shorted coupling cap at the phase inverter output.
Standard Test Procedure: can help you find and solve this problem.