Bias - need more help

RVA

Ambassador
I will start by saying I am sick of tube amps...again.

So when I got my Ceriatone amp, I set the bias at 23 each by adjusting the bias adjustent pot until they matched (I have attached the Ceriatone manual. See pages 11-13 for bias directions)

Today I changed the tubes. I had a matched quad handy, but I only needed 2 tubes. I grabed 2 and could not get them even close - closest was about 15mv away. I took away the high tube and grabbed another from the quad. Now I only get the mV between the tubes even at 17 mV - far shy of the 24 mV it was. What the hell is going on. I am so frustrated.

All help is greatly appreciated as I have run out of patience.
 

Attachments

I am OK now. I must have been measuring something wrong back there. They now move together - both up or down with the pot. I got them to 24 each and it is quiet. Thanks!
Thank goodness!!!
I feel better now!
I know that it’s been frustrating for you sir, but I’m glad to see your tenacity!
 
I really appreciate your help and support. I will learn if it doesn't kill me. I caught a 110v zap tonight!! After being told to be careful so many times, it scared the crap out of me!!

What did you touch?

Both hands in the chassis?

Yeah! One hand in the pocket sir! No death!
I’ve been bitten by lab equipment, and a TV....no fun.
 
Back
Top